SIA OpenIR  > 机器人学研究室
Studies on the transducers of clamp-on transit-time ultrasonic flow meter
Han JP(韩建平); Liu H(刘浩); Zhou YY(周圆圆); Zhang RM(张如美); Li ZJ(李长吉)
作者部门机器人学研究室
会议名称2014 4th IEEE International Conference on Information Science and Technology
会议日期April 26-28, 2014
会议地点Shenzhen, China
会议录名称Proceedings of 2014 4th IEEE International Conference on Information Science and Technology
出版者IEEE
出版地Piscataway, NJ, USA
2014
页码180-183
收录类别EI ; CPCI(ISTP)
EI收录号20144700232398
WOS记录号WOS:000364968700043
产权排序1
ISBN号978-1-4799-4808-6
关键词Ultrasonic Flow Meter Transducer Ultrasonic Frequency Incident Angle Installation Distance
摘要The clamp-on transit-time ultrasonic flow meters are widely applied for the advantage of noninvasive measurement and convenient deployment. Its key point lies on measuring of the time difference between the upstream and downstream. While high quality of the transducer transmitting/receiving ultrasonic signals is the premise of measuring time difference accurately. This paper studies on the main factors contributing to the uncertainty of the transducer’s output signal and focuses on the transducer’s frequency, incident angle and the separate distance. The selection principle of transducer’s frequency is presented by the analysis of the ultrasonic attention characteristics in the liquid. The incident angle range and precise installation distance of the transducers are calculated and analyzed by Snell’s law. Experiments are also carried out with the 1MHz transducers clamped on the aluminium pipe of 20mm outer diameter. The results show that the accurate calculation separate distance 18.16mm is effective to guarantee the output of high quality ultrasonic wave. If the axial installation error reaches more than 3mm, the one beam of ultrasonic signal cannot be guaranteed.
语种英语
引用统计
被引频次:3[WOS]   [WOS记录]     [WOS相关记录]
文献类型会议论文
条目标识符http://ir.sia.cn/handle/173321/15397
专题机器人学研究室
作者单位1.Department of Medical Devices and Information Center, Shenyang Institute of Automation, Chinese Academy of Sciences, South Towel Street No.114, Shenyang, China
2.Department of Information and Control Engineering, Shenyang Jianzhu University, Muddy South East Road No.9, Shenyang, China
3.Yingkou Jucheng Techonology Development of Teaching Co., LTD, Bohai Street No.98, Yingkou, China
推荐引用方式
GB/T 7714
Han JP,Liu H,Zhou YY,et al. Studies on the transducers of clamp-on transit-time ultrasonic flow meter[C]. Piscataway, NJ, USA:IEEE,2014:180-183.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Studies on the trans(189KB)会议论文 开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Han JP(韩建平)]的文章
[Liu H(刘浩)]的文章
[Zhou YY(周圆圆)]的文章
百度学术
百度学术中相似的文章
[Han JP(韩建平)]的文章
[Liu H(刘浩)]的文章
[Zhou YY(周圆圆)]的文章
必应学术
必应学术中相似的文章
[Han JP(韩建平)]的文章
[Liu H(刘浩)]的文章
[Zhou YY(周圆圆)]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Studies on the transducers of clamp-on transit-time ultrasonic flow meter.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。