摘要Solenoid-operated valves (SOVs) are widely used components in a variety of industries and systems. Though they are small components, their failure can lead to catastrophic failure of the system in which they are placed. Past studies have revealed the electromagnetic coil insulation to be a weakness, and prior work in the AC motor community on twisted pairs has shown that insulation capacitance measurements can reveal useful diagnostic information. Yet, no studies have tracked the impedance spectrum over an aging/degradation period, no methods are available to identify frequencies in the impedance spectrum to be used, there discussion about how to employ coil impedance to determine a degradation mechanism, nor has there been any quantifications of the mechanical properties due to degradation. This paper develops a method of detection of the aging of insulation in low-voltage electromagnetic coils when subjected to elevated temperature environmental conditions by assessing changes in the impedance spectrum. In this experiment, a solenoid valve was powered and subjected to an operating environment equal to its maximum operating temperature. The valve was periodically removed from the temperature chamber and the impedance spectrum measured. The complex impedance was split into its real and imaginary parts and the Spearman correlation coefficient was used to find regions of interest within the impedance spectrum. The results indicate that resistance and reactance provide information that can assist in condition-based maintenance procedures for electromagnetic coils. Furthermore, mechanical properties of the insulation are investigated and reveal differences in degradation due to environmental conditions.
语种英语
文献类型会议论文
条目标识符http://ir.sia.cn/handle/173321/18754
专题工业控制网络与系统研究室
通讯作者Jameson, N. Jordan
作者单位1.Center for Advanced Life Cycle Engineering, University of Maryland, College Park, MD, 20742, United States
2.Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, Liaoning, 110016, China
推荐引用方式
GB/T 7714
Jameson, N. Jordan,Azarian, Michael H.,Morillo, Carlos,et al. Health monitoring of solenoid valve electromagnetic coil insulation under thermal deterioration[C]:Society for Machinery Failure Prevention Technology,2016:1-25.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Health monitoring of(8822KB)会议论文 开放获取CC BY-NC-SA浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Jameson, N. Jordan]的文章
[Azarian, Michael H.]的文章
[Morillo, Carlos]的文章
百度学术
百度学术中相似的文章
[Jameson, N. Jordan]的文章
[Azarian, Michael H.]的文章
[Morillo, Carlos]的文章
必应学术
必应学术中相似的文章
[Jameson, N. Jordan]的文章
[Azarian, Michael H.]的文章
[Morillo, Carlos]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Health monitoring of solenoid valve electromagnetic coil insulation under thermal deterioration.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。