Robust mixed H2/ H∞ based optimal controller design for single-phase grid-connected converter
Li ZW(李忠文); Zang CZ(臧传治); Zeng P(曾鹏); Yu HB(于海斌); Li HP(李鹤鹏); Gao, Lin; Bai, Xiuwen
Department工业控制网络与系统研究室
Conference Name28th Chinese Control and Decision Conference, CCDC 2016
Conference DateMay 28-30, 2016
Conference PlaceYinchuan, China
Source PublicationProceedings of the 28th Chinese Control and Decision Conference, CCDC 2016
PublisherIEEE
Publication PlacePiscataway, NJ, USA
2016
Pages1230-1234
Indexed ByEI ; CPCI(ISTP)
EI Accession number20163602766304
WOS IDWOS:000383222301086
Contribution Rank1
ISSN1948-9439
ISBN978-1-4673-9714-8
KeywordSingle-phase Converter Mixed H2 / H∞ Uncertainty Optimal Control
AbstractIn order to integrate more and more renewable energy resources to the main grid, single-phase grid-connected converters (GCCs) have gained more attention. However, the controller for a single-phase GCC is much more difficult to design than for a three-phase GCC. Traditionally, proportional plus integral (PI) or proportional plus resonant (PR) are widely used to control a single-phase GCC system. However, both the PI and PR controlled GCC show some drawbacks, such as slow response speed, poor robust performance against the systems' uncertainties and exogenous disturbance. In this paper, the detail state-space model of a single-phase GCC system is built, which includes the uncertainty and disturbance in the system to accurately reflect the practical system conditions. Then, robust mixed H2/H∞ optimal control technique is applied to design a full-state feedback controller for a single-phase grid-connected converter. The performance of proposed control method is evaluated by simulation. Simulation results demonstrate that the proposed control method has much more improved transient and steady state performance than PI controller.
Language英语
Citation statistics
Cited Times:1[WOS]   [WOS Record]     [Related Records in WOS]
Document Type会议论文
Identifierhttp://ir.sia.cn/handle/173321/19175
Collection工业控制网络与系统研究室
Corresponding AuthorLi ZW(李忠文)
Affiliation1.Lab. of Networked Control Systems, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang, 110016, China
2.University of Chinese Academy of Sciences, Beijing, 100049, China
3.Yingkou Electric Power Supply Company, State Grid Liaoning Electric Power Supply Company LTD, China
Recommended Citation
GB/T 7714
Li ZW,Zang CZ,Zeng P,et al. Robust mixed H2/ H∞ based optimal controller design for single-phase grid-connected converter[C]. Piscataway, NJ, USA:IEEE,2016:1230-1234.
Files in This Item: Download All
File Name/Size DocType Version Access License
Robust mixed H2 H∞ b(360KB)会议论文 开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Li ZW(李忠文)]'s Articles
[Zang CZ(臧传治)]'s Articles
[Zeng P(曾鹏)]'s Articles
Baidu academic
Similar articles in Baidu academic
[Li ZW(李忠文)]'s Articles
[Zang CZ(臧传治)]'s Articles
[Zeng P(曾鹏)]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Li ZW(李忠文)]'s Articles
[Zang CZ(臧传治)]'s Articles
[Zeng P(曾鹏)]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Robust mixed H2 H∞ based optimal controller design for single-phase grid-connected converter.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.