资助机构Foundation of the State Key Laboratory of Robotics [2017-O01] ; Foundation of the State Key Laboratory of Materials Processing and Die & Mold Technology [P2018-011] ; State Key Laboratory of CAD CG [A1718] ; Liaoning Province Doctor Startup Fund [201601389] ; Research Foundation for Clinical Diagnosis and Treatment of Anemia for Young Physicians [LIM-SS-16001]
摘要

OBJECTIVES: No studies have compared monoaxial and polyaxial pedicle screws with regard to the von Mises stress of the instrumentation, intradiscal pressures of the adjacent segment and adjacent segment degeneration. METHODS: Short-segment monoaxial/polyaxial pedicle screw fixation techniques were compared using finite element methods, and the redistributed T11-L1 segment range of motion, largest maximal von Mises stress of the instrumentation, and intradiscal pressures of the adjacent segment under displacement loading were evaluated. Radiographic results of 230 patients with traumatic thoracolumbar fractures treated with these fixations were reviewed, and the sagittal Cobb's angle, vertebral body angle, anterior vertebral body height of the fractured vertebrae and adjacent segment degeneration were calculated and evaluated. RESULTS: The largest maximal values of the von Mises stress were 376.8 MPa for the pedicle screws in the short-segment monoaxial pedicle screw fixation model and 439.9 MPa for the rods in the intermediate monoaxial pedicle screw fixation model. The maximal intradiscal pressures of the upper adjacent segments were all greater than those of the lower adjacent segments. The maximal intradiscal pressures of the monoaxial pedicle screw fixation model were larger than those in the corresponding segments of the normal model. The radiographic results at the final follow-up evaluation showed that the mean loss of correction of the sagittal Cobb's angle, vertebral body angle and anterior vertebral body height were smallest in the intermediate monoaxial pedicle screw fixation group. Adjacent segment degeneration was less likely to be observed in the intermediate polyaxial pedicle screw fixation group but more likely to be observed in the intermediate monoaxial pedicle screw fixation group. CONCLUSION: Smaller von Mises stress in the pedicle screws and lower intradiscal pressure in the adjacent segment were observed in the polyaxial screw model than in the monoaxial pedicle screw fixation spine models. Fracture-level fixation could significantly correct kyphosis and reduce correction loss, and adjacent segment degeneration was less likely to be observed in the intermediate polyaxial pedicle screw fixation group.

语种英语
WOS标题词Science & Technology ; Life Sciences & Biomedicine
WOS类目Medicine, General & Internal
关键词[WOS]Lumbar Interbody Fusion ; Adjacent Disc Degeneration ; Burst Fractures ; Spinal-fusion ; Early Failure ; Follow-up ; Instrumentation ; Level ; Efficacy ; Disease
WOS研究方向General & Internal Medicine
引用统计
被引频次:1[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.sia.cn/handle/173321/21227
专题机器人学研究室
通讯作者Wang HW(王洪伟)
作者单位1.Department of Orthopedics, General Hospital of Shenyang Military Area Command of Chinese PLA, Shenyang, Liaoning, 110016, China
2.State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Science, Shenyang, Liaoning, 110016, China
3.National Research Center for Rehabilitation Aids, Beijing, 100176, China
4.Department of Orthopedics, Xinqiao Hospital, the Third Military Medical University, Chongqing, 400037, China.
推荐引用方式
GB/T 7714
Wang HW,Zhao YW,Mo, Zhongjun,et al. Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review[J]. CLINICS,2017,72(10):609-617.
APA Wang HW.,Zhao YW.,Mo, Zhongjun.,Han JD.,Chen Y.,...&Xiang LB.(2017).Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review.CLINICS,72(10),609-617.
MLA Wang HW,et al."Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures: a finite element study and clinical radiographic review".CLINICS 72.10(2017):609-617.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
Comparison of short-(3866KB)期刊论文作者接受稿开放获取ODC PDDL浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Wang HW(王洪伟)]的文章
[Zhao YW(赵忆文)]的文章
[Mo, Zhongjun]的文章
百度学术
百度学术中相似的文章
[Wang HW(王洪伟)]的文章
[Zhao YW(赵忆文)]的文章
[Mo, Zhongjun]的文章
必应学术
必应学术中相似的文章
[Wang HW(王洪伟)]的文章
[Zhao YW(赵忆文)]的文章
[Mo, Zhongjun]的文章
相关权益政策
暂无数据
收藏/分享
文件名: Comparison of short-segment monoaxial and polyaxial pedicle screw fixation combined with intermediate screws in traumatic thoracolumbar fractures.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。