SIA OpenIR  > 海洋信息技术装备中心
A Novel Self-Calibration Method for Acoustic Vector Sensor
Zhang Y(张瑶); Fu, Jin; Li GN(李冠男)
作者部门海洋信息技术装备中心
发表期刊MATHEMATICAL PROBLEMS IN ENGINEERING
ISSN1024-123X
2018
卷号2018页码:1-9
收录类别SCI ; EI
EI收录号20181505000151
WOS记录号WOS:000428322600001
产权排序1
资助机构State Key Laboratory of Robotics Foundation [2016-Z08, 2017-Z05] ; Basic Research Project of Technology [JSJL2016604B003] ; Heilongjiang Postdoctoral Research Startup Fund [LBH-Q15025] ; Open Fund of Qingdao National Laboratory for Marine Science and Technology [QNLM2016-0RP0 102]
摘要The acoustic vector sensor (AVS) can measure the acoustic pressure field's spatial gradient, so it has directionality. But its channels may have nonideal gain/phase responses, which will severely degrade its performance in finding source direction. To solve this problem, in this study, a self-calibration algorithm based on all-phase FFT spectrum analysis is proposed. This method is "self-calibrated" because prior knowledge of the training signal's arrival angle is not required. By measuring signals from different directions, the initial phase can be achieved by taking the all-phase FFT transform to each channel. We use the amplitude of the main spectrum peak of every channel in different direction to formulate an equation; the amplitude gain estimates can be achieved by solving this equation. In order to get better estimation accuracy, bearing difference of different training signals should be larger than a threshold, which is related to SNR. Finally, the reference signal's direction of arrival can be estimated. This method is easy to implement and has advantage in accuracy and antinoise. The efficacy of this proposed scheme is verified with simulation results.
语种英语
引用统计
文献类型期刊论文
条目标识符http://ir.sia.cn/handle/173321/21735
专题海洋信息技术装备中心
通讯作者Zhang Y(张瑶)
作者单位1.State Key Laboratory of Robotics, Shenyang Institute of Automation, Chinese Academy of Sciences, Shenyang 110016, China
2.National Laboratory of Underwater Acoustic Technology, Harbin Engineering University, Harbin 150001, China
推荐引用方式
GB/T 7714
Zhang Y,Fu, Jin,Li GN. A Novel Self-Calibration Method for Acoustic Vector Sensor[J]. MATHEMATICAL PROBLEMS IN ENGINEERING,2018,2018:1-9.
APA Zhang Y,Fu, Jin,&Li GN.(2018).A Novel Self-Calibration Method for Acoustic Vector Sensor.MATHEMATICAL PROBLEMS IN ENGINEERING,2018,1-9.
MLA Zhang Y,et al."A Novel Self-Calibration Method for Acoustic Vector Sensor".MATHEMATICAL PROBLEMS IN ENGINEERING 2018(2018):1-9.
条目包含的文件 下载所有文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
A Novel Self-Calibra(2452KB)期刊论文作者接受稿开放获取ODC PDDL浏览 下载
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Zhang Y(张瑶)]的文章
[Fu, Jin]的文章
[Li GN(李冠男)]的文章
百度学术
百度学术中相似的文章
[Zhang Y(张瑶)]的文章
[Fu, Jin]的文章
[Li GN(李冠男)]的文章
必应学术
必应学术中相似的文章
[Zhang Y(张瑶)]的文章
[Fu, Jin]的文章
[Li GN(李冠男)]的文章
相关权益政策
暂无数据
收藏/分享
文件名: A Novel Self-Calibration Method for Acoustic Vector Sensor.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。