SIA OpenIR  > 光电信息技术研究室
Analysis and Characterization of Electromagnetic Compatibility of the In Vitro Diagnostic Medical Device
Guo, Yu1; Guo, Jian1; Qi F(祁峰)2; Wang, Lirong3; Chen, Xiaohe1
Department光电信息技术研究室
Conference NameProgress in Electromagnetics Research Symposium - Fall (PIERS - FALL)
Conference DateNovember 19-22, 2017
Conference PlaceSingapore, SINGAPORE
Author of SourceInst Elect & Elect Engineers, Nanyang Technol Univ, Electromagnet Acad, Inst Elect & Elect Engineers Geoscience & Remote Sensing Soc, Comp Simulat Technol, Off Naval Res Global, Interhorizon Corp Pte Ltd, Linbou Nearfield Technol Co Ltd, Rohde & Schwarz, YSL Photon, Zhejiang Univ, Electromagnet Acad, Singapore Exhibit & Convent Bur, YourSingapore
Source Publication2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - FALL (PIERS - FALL)
PublisherIEEE
Publication PlaceNew York
2017
Pages1924-1927
Indexed ByEI ; CPCI(ISTP)
EI Accession number20181605018071
WOS IDWOS:000428518301174
Contribution Rank2
ISSN1559-9450
ISBN978-1-5386-1211-8
AbstractThis paper analyses the electromagnetic compatibility (EMC) of the In Vitro Diagnostic (IVD) medical device, according to the EMC test results. It is demonstrated that the auxiliary equipment (AE) weakens the EMC of the IVD device. And the electromagnetic interference (EMI) noise is conducted through the data cables connecting the IVD device to the AE. Furthermore, this paper proposes a method to enhance the EMC of IVD device by using the ferrite magnetic rings. Finally, the test results show that the cable must be looped around the rings in proper turns, for an excellent effect on improving the EMC.
Language英语
Citation statistics
Document Type会议论文
Identifierhttp://ir.sia.cn/handle/173321/22060
Collection光电信息技术研究室
Corresponding AuthorGuo, Yu
Affiliation1.Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, China;
2.Shenyang Institute of Automation, Chinese Academy of Sciences, China;
3.School of Electronic and Information Engineering, Soochow University, China
Recommended Citation
GB/T 7714
Guo, Yu,Guo, Jian,Qi F,et al. Analysis and Characterization of Electromagnetic Compatibility of the In Vitro Diagnostic Medical Device[C]//Inst Elect & Elect Engineers, Nanyang Technol Univ, Electromagnet Acad, Inst Elect & Elect Engineers Geoscience & Remote Sensing Soc, Comp Simulat Technol, Off Naval Res Global, Interhorizon Corp Pte Ltd, Linbou Nearfield Technol Co Ltd, Rohde & Schwarz, YSL Photon, Zhejiang Univ, Electromagnet Acad, Singapore Exhibit & Convent Bur, YourSingapore. New York:IEEE,2017:1924-1927.
Files in This Item: Download All
File Name/Size DocType Version Access License
Analysis and Charact(232KB)会议论文 开放获取CC BY-NC-SAView Download
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Guo, Yu]'s Articles
[Guo, Jian]'s Articles
[Qi F(祁峰)]'s Articles
Baidu academic
Similar articles in Baidu academic
[Guo, Yu]'s Articles
[Guo, Jian]'s Articles
[Qi F(祁峰)]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Guo, Yu]'s Articles
[Guo, Jian]'s Articles
[Qi F(祁峰)]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: Analysis and Characterization of Electromagnetic Compatibility of the In Vitro Diagnostic Medical Device.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.